Prime-Time Electronic Trap Priming Assembly Flush Mount

PT-4 - PT-12
PT-4 - PT12 Flush Mount

It's PRIME-TIME to meet your floor drain trap priming needs. This unique trap priming manifold is available in 4 through 12 opening configurations and all the contractor needs to do is simply supply the potable water and power, Precision supplies the rest...

"... Automatically maintains a constant water seal in floor drain traps."

The PRIME-TIME PRIMING MANIFOLD will supply a minimum of 2 oz. of potable water at 20 P.S.I.G. at a preset factory setting of 6 seconds every 24 hours. The entire manifold is assembled in a steel cabinet ready to be either surface, or flush wall mounted. The Priming assembly must be mounted above the finished floor.

Description:

The Electronic Priming Manifold pictured is available in five separate configurations. The model PT-4 offers a four opening manifold capable of priming four separate floor drain traps from a single control unit. Models PT-6 thru PT-12 provide the same features only expanding to a total of twelve floor drains. All manifolds are available in either 1/2" or 5/8" compression fittings.

Features:
  • Serves up to 12 Drains
  • Atmospheric Vacuum Breaker
  • Pre-Set 24 Hour Change
  • Manual Over Ride Switch
  • 120V/220V Solenoid Valve
  • 120V/220V 3/Wire Connection
  • 3/4" FNP Connection
  • Calibrated Manifold for Equal Water Distribution
  • 5/8" or 1/2" Outlet Compression Fittings
Application:
SPECIFICATIONS & INSTALLATION
Cabinet: Standard 3-3/8" Depth - Dry Wall Flush Mount (In Wall)
Fire Rated 6" Depth - FLush Mountain (In Wall)
Cabinet Material: 16 Gauge Steel, Galvanized
Inlet: 3/4" NPT Female
ANSI/ASME BI.20.1
Outlet: 5/8" or 1/2" inch compression fitting.
Manifold: 3/4" Type "L" Copper Tubing
ASTM B88
Soldered Joints: 95-5 Lead Free Containing Lead Not IN Excess of 0.2%
Electrical Component: .2 Amp Circuit Breaker, Test Switch, Timer, Solenoid Valve marked as UL Listed
Backflow Prevention: Anti-Siphon Atmospheric Vacuum Breaker Meets Los Angeles Code, IAPMO, New York Board of Standards, ASSE 1001 and CSA.
Access Door: Optional: Prime Coat, Stainless Steel, and Fire Rated.
INSTALLATION:
NOTE: UNIT MUST BE INSTALLED PLUMB. - MUST BE INSTALLED WITH ACCESS. - All PRIME-TIME Flush Mount units are available in Fire Rated Cabinets - 6" in Depth. The Priming assembly must be mounted above the finished floor.
 
PART NUMBERS & SPECIFICATIONS
 
PART NUMBER Manifold Opening Manifold FIttings Dimensions
PT-4 4 1/2" or 5/8 14"W x 16"H x 3-3/8"D
PT-6 6 1/2" or 5/8 14"W x 16"H x 3-3/8"D
 PT-8  8  1/2" or 5/8  14"W x 16"H x 3-3/8"D
 PT-10  10  1/2" or 5/8  14"W x 16"H x 3-3/8"D
 PT-12  12  1/2" or 5/8  14"W x 16"H x 3-3/8"D
     
 
PT-6
Accessories
Can't Find what you are looking for?
Please contact us at 503-328-6705 for TECHNICAL/SALES Support.